B&M Technical Services, Inc.

  • Home
  • Expert Services
    • Services Overview
    • Pump Rebuilds
    • Calibration and Testing
    • Cross Connection and Backflow Preventers
    • Lift Station Upgrade
    • SCADA
  • Product Partners
    • Product Overview
    • Crane Pumps & Systems
    • MPE, Inc. >
      • MPE Controllers
      • MPE Phase Monitors
      • MPE Voltage Monitors
      • MPE Duplex/Triplex Alternators
      • MPE Time Delay Relays
      • MPE Level Measurement
      • MPE Intrinsically Safe Controls
      • MPE Special Controls
      • MPE Pump Monitor Relay
    • ShinMaywa >
      • ShinMaywa CNWX Pumps
      • ShinMaywa CNXH/CNX Pumps
      • ShinMaywa SM/SME Mixers
      • ShinMaywa Dewatering Pumps
    • Cattron
    • Eastech Flow Controls
    • Neptune Screens
    • Micronics
    • Allen Bradley
  • Project Portfolio
    • New Lift Stations
    • Can Station Upgrades
    • SCADA & Telemetry Systems
    • Microstrainers
  • Contact
    • Contact
    • About Us
    • FAQ
    • Careers >
      • Employees Portal
      • Position Descriptions
      • Application

Office: 715.228.7604
Fax: 715.228-3418

364 Industrial Drive
PO Box 48
Coloma, WI 54930

Special Controls

Adjustable Transmitter

Picture
The Adjustable Transmitter is a device used in an analog current loop to test, calibrate or demo equipment. The AT4201 simulates an analog field device such as a Pressure Transducer or Temperature Transmitter. When placed in the analog current loop, the Adjustable Transmitter regulates the current in the loop to the setting on the knob from 4 to 20 mA. When a more precise setting is required, place an ammeter in the current loop to display the loop current.

Battery Operated Alarm with Charger

Picture
The BOAC unit is a solid state device that charges the backup battery used in a 12 V DC alarm system that has an alarm strobelight and horn. The BOAC unit activates the alarm strobe light and horn automatically when there is a loss of 120 V AC power. Upon loss of 120 V AC power, there is a time delay of approximately 5 seconds when switching from the charging circuit to the battery powered alarm circuit. This delay prevents momentary power glitches from causing nuisance alarms. During an alarm with a loss of 120 V AC, the alarm strobe light and horn are powered by the battery. Battery power is conserved by operating the horn intermittently, on for 2 seconds, and then off for 2 seconds. An alarm contact closure across pins 3 and 10 with 120 V AC applied will activate the alarm strobe light and horn. After an alarm, with 120 V AC applied, the BOAC will recharge the 12 V DC backup battery. A push-to-test button is provided to verify system operation. When pushed, the strobelight is activated and the horn operates intermittenly; 2 seconds on, 2 seconds off.

Flasher

Picture
The Flasher provides a simple means of achieving a 120 V AC alarm flash circuit, without the high cost of a strobelight. The most common application would be flashing an incandescent light bulb. The rate of flash is approximately 30 flashes per minute.

Power Supply

Picture
The PS100 is a compact, regulated, linear 24 V DC power supply, capable of supplying up to 100 mA of current. It operates from 120 V AC and has a solid state resettable fuse on its output. The 24 V DC output is transient protected. The PS100 plugs into a 12 pin base, allowing fast installation and easy servicing.