B&M Technical Services, Inc.

  • Home
  • Expert Services
    • Services Overview
    • Pump Rebuilds
    • Calibration and Testing
    • Cross Connection and Backflow Preventers
    • Lift Station Upgrade
    • SCADA
  • Product Partners
    • Product Overview
    • Crane Pumps & Systems
    • MPE, Inc. >
      • MPE Controllers
      • MPE Phase Monitors
      • MPE Voltage Monitors
      • MPE Duplex/Triplex Alternators
      • MPE Time Delay Relays
      • MPE Level Measurement
      • MPE Intrinsically Safe Controls
      • MPE Special Controls
      • MPE Pump Monitor Relay
    • ShinMaywa >
      • ShinMaywa CNWX Pumps
      • ShinMaywa CNXH/CNX Pumps
      • ShinMaywa SM/SME Mixers
      • ShinMaywa Dewatering Pumps
    • Eastech Flow Controls
    • Neptune Screens
    • Allen Bradley
  • Project Portfolio
    • New Lift Stations
    • Can Station Upgrades
    • SCADA & Telemetry Systems
    • Microstrainers
  • Contact
    • Contact
    • About Us
    • FAQ
    • Careers >
      • Position Descriptions
      • Application

Office: 715.228.7604
Fax: 715.228-3418

364 Industrial Drive
PO Box 48
Coloma, WI 54930

MPE Pump Monitor Relay

4/13/2012

0 Comments

 
Picture
I can't believe I haven't blogged about MP Electronics's latest new product - the Pump Monitor Relay.  This relay is a nifty component that monitors the critical operations of your submersible pump, and provides alarms when something isn't right.  The relay monitors both over temperature and seal leakage. 

How's it work?  For the Motor Over Temperature Alarm, the Pump Monitor Relay applies a low voltage DC signal to the Motor Thermal Sensor to check its status. If the Pump Monitor Relay detects that the Motor Thermal Sensor contacts are closed (normal condition), the Overtemp indicator remains off, and the Overtemp Relay is energized, closing the contacts between terminals 2 and 11.
When the Motor Thermal Sensor contacts open (Over Temperature condition), the Overtemp Indicator is turned on and the Overtemp Alarm Relay is de-energized, opening the contacts between terminals 2 and 11, and closing the contacts between terminals 2 and 1.

When the Over Temperature condition has cleared, the Pump Monitor Relay will reset based upon the position of Alarm Reset Mode Select Switch (Auto or Manual). When in the Auto position, the Overtemp Alarm resets automatically. When the switch is in the Manual position, the Overtemp Reset Push-button must be pushed for approximately 1.5 seconds to clear the alarm.

For the Seal Leakage Alarm, the Pump Monitor Relay detects moisture inside a pump motor by using a low voltage AC signal to measure the resistance across Leakage Probes #1 and #2, or between the Leakage Probe(s) and the grounded motor housing. A Seal Leakage condition is considered present when the amount of moisture in the motor causes the resistance between terminals 6 and 5 to drop below the setting of the potentiometer. When this occurs, the Pump Monitor Relay turns on the Leakage Indicator and energizes the Leakage Alarm Relay, closing the contacts between terminals 9 and 10.

The alarm trip point may be set by the following procedure: Isolate the Leakage Probe from terminal 6. Connect a resistor with the desired trip value across terminals 5 and 6. Slowly adjust the potentiometer to the point where the alarm turns on. Remove the resistor and reconnect the Leakage Probe(s) to terminal 6.

Check out the short clip below to watch to MP Electronic's President John Evans showcasing the Pump Monitor Relay device.  We're looking forward to using this component in projects going forward.  It's got all the hallmark benefits of MPE - versatile, user friendly, simple to use, logical, and American-made.

For more information, you can get the specification sheets from the MPE website or give us a call.  I've also created a new page called Pump Monitor Relay on our website under our MPE Products header that you can access for reference at any time going forward.  
Source: MPE Website
0 Comments

Your comment will be posted after it is approved.


Leave a Reply.

    Archives

    July 2017
    June 2017
    May 2017
    April 2017
    March 2017
    February 2017
    January 2017
    December 2016
    November 2016
    October 2016
    September 2016
    August 2016
    July 2016
    June 2016
    May 2016
    April 2016
    March 2016
    February 2016
    January 2016
    December 2015
    November 2015
    October 2015
    September 2015
    August 2015
    July 2015
    June 2015
    May 2015
    April 2015
    March 2015
    February 2015
    January 2015
    December 2014
    November 2014
    October 2014
    September 2014
    August 2014
    July 2014
    June 2014
    May 2014
    April 2014
    March 2014
    February 2014
    December 2013
    November 2013
    September 2013
    August 2013
    July 2013
    June 2013
    May 2013
    April 2013
    March 2013
    February 2013
    January 2013
    December 2012
    November 2012
    October 2012
    September 2012
    August 2012
    July 2012
    June 2012
    May 2012
    April 2012
    March 2012
    February 2012
    January 2012
    December 2011
    November 2011
    October 2011
    September 2011
    August 2011
    July 2011
    June 2011
    April 2011
    March 2011
    February 2011
    January 2011

Connect with us

Picture
Our Blog
Office: 715.228.7604
Fax: 715.228-3418

364 Industrial Drive, PO Box 48
Coloma, WI 54930

Search our site

Created and Maintained by Katie Gruber, B&M Technical Services Inc.